110kV power transformers are widely used in electrical substations, power transmission networks, renewable energy projects, and industrial power distribution systems. During operation, transformer cores and windings generate heat due to no-load and load losses. An efficient cooling system is therefore essential to maintain operating temperatures, protect insulation materials, and ensure long-term transformer reliability.
As a critical component of oil-immersed transformer cooling systems, radiator panels transfer heat from transformer oil to the surrounding air through natural or forced convection.
Choosing a reliable 110kV power transformer radiator supplier is important for transformer manufacturers and engineering contractors. Radiator dimensions, cooling capacity, oil circulation, welding quality, and pressure resistance must all meet the technical requirements of the transformer.
RADIASTAR specializes in manufacturing transformer radiators, radiator panels, and oil-immersed transformer cooling components. With customized OEM manufacturing capabilities, RADIASTAR provides radiator solutions based on customer drawings, technical specifications, and project requirements.
110kV power transformers are commonly installed in grid substations, industrial facilities, renewable energy plants, and regional power distribution networks.
Their cooling systems must provide sufficient heat dissipation under different operating conditions.
Typical applications include:
Power Grid Substations
110kV/10kV, 110kV/20kV, and 110kV/35kV transformers are commonly used for voltage conversion in transmission and distribution networks. Radiator banks help maintain the required oil temperature during continuous operation.
Renewable Energy Projects
Solar and wind power plants use step-up transformers to connect generated electricity to high-voltage grids. Reliable radiator systems support stable transformer operation under varying load conditions.
Industrial Power Supply
Steel plants, mining facilities, chemical factories, and other industrial users require reliable power transformers. Radiator configurations must accommodate the specified operating loads and environmental conditions.
Utility and Infrastructure Projects
Large substations and regional power infrastructure projects require customized cooling systems designed according to transformer capacity, losses, ambient temperature, and installation conditions.
Different 110kV transformers may have significantly different cooling requirements, even when they share the same voltage class.
For example, a 110kV 31.5MVA transformer and a 110kV 63MVA transformer do not necessarily use the same radiator configuration.
Radiator selection depends on transformer losses, rated capacity, cooling method, temperature rise limits, and installation space.
RADIASTAR provides customized radiator manufacturing according to the following parameters:
| Technical Parameter | RADIASTAR Product Range |
|---|---|
| Product Type | Transformer Radiator Panels |
| Application | Oil-Immersed Transformers |
| Transformer Capacity | 50 kVA–500 MVA |
| Voltage Class | 10–500 kV |
| Radiator Height | 500–3500 mm |
| Center Distance | 300–3500 mm |
| Panel Width | 120 / 140 / 160 / 180 mm, customized |
| Panel Thickness | 1.2 / 1.5 / 2.0 / 2.5 mm |
| Panel Quantity | 5–36 panels |
| Cooling Methods | ONAN / ONAF |
| Connection | Flange / Welding |
| Surface Treatment | Shot Blasting and Painting |
| Customization | OEM / ODM |
Note: The above specifications represent RADIASTAR’s available manufacturing range, not a fixed configuration for all 110kV transformers. Final specifications are subject to engineering drawings and customer requirements.
The cooling method is one of the most important considerations when selecting radiator panels for high-voltage transformers.
Two commonly used cooling configurations are ONAN and ONAF.
| Parameter | ONAN | ONAF |
|---|---|---|
| Full Name | Oil Natural Air Natural | Oil Natural Air Forced |
| Oil Circulation | Natural | Natural |
| Air Circulation | Natural | Forced |
| Cooling Fans | Not required | Required |
| Cooling Performance | Natural convection | Enhanced air cooling |
| Typical Application | Standard cooling | Higher cooling demand |
ONAN Cooling System
In an ONAN cooling system, heated transformer oil rises naturally into the upper radiator header. As the oil passes through radiator panels, heat transfers to the surrounding air. The cooled oil then returns to the transformer tank.
ONAF Cooling System
In an ONAF cooling system, the oil circulation remains natural, while cooling fans force air across the radiator surfaces. This increases heat transfer and improves cooling performance.
For 110kV power transformers, the cooling configuration should be determined according to rated capacity, losses, required temperature rise, and operating conditions.
RADIASTAR manufactures radiator panels suitable for both ONAN and ONAF transformer cooling applications.
For transformer manufacturers and procurement teams, selecting a radiator supplier involves more than comparing product prices.
The following factors should be considered.
110kV transformer projects often involve customized radiator dimensions and connection structures.
A qualified supplier should be able to manufacture radiator panels according to:
Customer-approved engineering drawings.
Required radiator height and center distance.
Panel width and thickness.
Header dimensions and connection positions.
Mounting structures and flange specifications.
RADIASTAR supports customized radiator manufacturing for different transformer designs.
Radiator panels must maintain structural integrity during transportation, installation, and transformer operation.
Welding quality is particularly important because defective welds may result in oil leakage or pressure-related failures.
Manufacturing quality control should include weld inspection, dimensional verification, and pressure testing according to applicable requirements.
Transformer radiators operate as part of an oil-filled cooling circuit.
They must withstand specified operating pressures and testing conditions without leakage or unacceptable deformation.
RADIASTAR incorporates pressure testing and leakage inspection into its radiator quality-control process.
110kV transformers are frequently installed outdoors and may operate in humid, coastal, industrial, or high-temperature environments.
Proper surface preparation and protective coatings help improve corrosion resistance.
Common manufacturing processes include:
Shot blasting and surface preparation.
Anti-corrosion primer application.
Protective topcoat painting.
Coating thickness inspection.
Customized coating systems can be selected according to project specifications and environmental conditions.
Manufacturing consistency is essential for supplying radiator panels to large power transformer projects.
RADIASTAR focuses on key manufacturing and inspection procedures to ensure product quality.
| Production Stage | Main Process | Quality Control |
|---|---|---|
| 1. Material Preparation | Steel sheet cutting | Material and thickness inspection |
| 2. Panel Forming | Pressing and forming | Dimensional inspection |
| 3. Welding | Automated and manual welding | Weld quality inspection |
| 4. Assembly | Header and panel connection | Structural inspection |
| 5. Pressure Testing | Hydraulic testing | Pressure resistance and leakage |
| 6. Surface Treatment | Shot blasting and painting | Coating inspection |
| 7. Final Inspection | Packaging and preparation | Appearance and dimensional verification |
Each manufacturing stage contributes to the reliability and service performance of the finished radiator assembly.
For OEM projects, RADIASTAR can coordinate production according to customer-approved drawings, technical documents, and inspection requirements.
RADIASTAR specializes in transformer tanks, radiator panels, and oil-immersed transformer cooling components.
The company provides customized manufacturing solutions for transformer manufacturers, electrical equipment suppliers, and power engineering contractors.
Key advantages of RADIASTAR include:
1. Wide Product Application
Radiator solutions for distribution transformers, medium-voltage transformers, and large power transformers, with an available application range of 50kVA–500MVA.
2. Customized OEM Manufacturing
Radiator dimensions, panel quantity, center distance, connection structures, and coating specifications can be customized according to customer drawings.
3. Multiple Product Configurations
Different radiator designs and specifications are available to meet various transformer cooling requirements.
4. Quality Inspection Capabilities
Manufacturing quality control includes pressure testing, leakage inspection, dimensional verification, and surface coating inspection.
5. International Project Support
RADIASTAR serves overseas transformer manufacturers and electrical equipment customers with customized radiator solutions and export-oriented manufacturing support.
Whether you need standard radiator panels or customized cooling components for a 110kV power transformer, RADIASTAR can support your project from technical drawing review to finished product manufacturing.
To provide an accurate quotation and suitable radiator configuration, buyers should prepare the following information:
| Required Information | Example |
|---|---|
| Transformer Voltage | 110kV |
| Transformer Capacity | 31.5 / 40 / 50 / 63 MVA |
| Cooling Method | ONAN / ONAF |
| No-Load Loss | According to transformer design |
| Load Loss | According to transformer design |
| Radiator Height | Customer specification |
| Center Distance | Customer specification |
| Panel Width | Customer specification |
| Panel Quantity | According to thermal design |
| Connection Type | Flange / Welding |
| Surface Treatment | Required coating system |
| Delivery Destination | Country / Port |
For more accurate engineering evaluation, buyers are encouraged to provide:
Transformer general arrangement drawings.
Existing radiator drawings.
Technical specifications.
Cooling system requirements.
Applicable standards and inspection requirements.
RADIASTAR can review your drawings and provide customized radiator manufacturing solutions according to your project requirements.
Selecting the right radiator supplier is essential for maintaining the cooling performance and operational reliability of 110kV oil-immersed power transformers.
Radiator design must consider transformer losses, cooling methods, heat dissipation requirements, oil circulation, structural strength, and corrosion protection.
RADIASTAR provides customized transformer radiator panels for applications ranging from distribution transformers to large power transformers up to 500 MVA.
With OEM manufacturing capabilities, multiple product configurations, and quality inspection procedures, RADIASTAR supports transformer manufacturers and engineering contractors with reliable transformer cooling components.
Looking for a reliable 110kV power transformer radiator supplier?
Contact RADIASTAR for customized OEM radiator panels, technical specifications, and competitive factory quotations.
Website: https://www.radiastar.com/
Product: Transformer Radiator Panels
Application: 110kV Power Transformers
Service: OEM / ODM Customization